BI4OAE HAM Toolbox EN

Power & Signal UnitsConversionTool 04 Pure Local

Watts are a dead end on a logarithmic scale; dBm is the language of link budgets. This page converts between them and maps S-meter readings onto dBm.

Three-way conversion

—

Relationships:dBm = 10·log₁₀(P_mW);dBW = dBm − 30;P_W = 10^(dBW/10)。
Remember three anchors:、30 dBm = 1 W、10 dBm = 10 mW; doubling the power = +3 dB.

S-meter (signal strength)

The S-meter is a logarithmic scale of receiver signal strength, used for the "S" in CW and digital RST reports. Enter either an S value or dBm.

—

Standard sensitivity reference:−105 dBm is about S9. Receivers vary by more than 20 dB, so S readings are only meaningful when compared on the same receiver with the same transmitter. Always log the RST report — it is the only way to review propagation conditions later.

Common reference levels

ItemTypical ValuedBmComment

Click any row to load it into the converter above. dBm figures are estimates based on typical amateur equipment; real measurements vary widely by model, so treat them as order-of-magnitude only.

Receiver sensitivity quick reference

Device / bandSensitivityStatus
Communications-grade receiver (HF, 0.2–30 MHz)−131 ~ −139 dBmExcellent
Amateur HF transceiver−121 ~ −131 dBmGood
Entry-level HF transceiver−109 ~ −121 dBmFair
VHF/UHF handheld−109 ~ −116 dBmFair
SDR receiver (wideband)−125 ~ −135 dBmExcellent
All-band receiver (SDR-4 class)−130 ~ −140 dBmExcellent

Note: sensitivity is usually quoted as "NTSC 12 dB SINAD" or "CW 0.5 μV", and the two cannot be converted directly — SSB sensitivity is typically 10 dB worse than CW. The minimum signal on a datasheet represents the limit of audibility only.